Verify PoE Switch for positive or negative voltage input.
⚠️ WARNING: Potential Electrical Shock HazardOverview
Under specific network infrastructure configurations and physical mounting conditions, electrical potential can pass through the chassis grounding path of Elo I-Series devices when powered by the Gen 2 Power-over-Ethernet (PoE) Adapter. Installers, operators, or service technicians touching exposed metal mounting hardware may experience an electrical shock.
Affected Products & Components
-
PoE Adapter: Gen 2 PoE Adapter — Part Number:
E669163 -
Elo I-Series 5 Steel Models:
- 10-inch I-Series 5 Steel — Part Number:
E177025 - 15-inch I-Series 5 Steel — Part Number:
E176245 - 22-inch I-Series 5 Steel — Part Number:
E176640
- 10-inch I-Series 5 Steel — Part Number:
- Note: Other metal-mounted I-Series configurations may also be susceptible if the environmental conditions below are met.
Under What Conditions Does This Issue Occur?
This behavior only occurs when both of the following conditions are simultaneously met:
-
Positively Grounded PoE Network Switch: The device is connected to a Power Sourcing Equipment (PSE) switch with a positively referenced/positively grounded DC power architecture that supplies a negative voltage potential to Power Devices (PD’s). Known examples include:
- Cisco Catalyst
WS-C2960X-48FPD-L - Cisco Catalyst
C9200L-48PL-4X
- Cisco Catalyst
- Exposed Conductive Grounding Points: The unit is mounted using uninsulated, conductive hardware (such as metal standoffs, brackets, or exposed metal fasteners) that can be directly contacted by operators or technicians.
If your PoE switch uses conventional negative-referenced/isolated input voltage circuitry, this voltage leakage does not occur and no shock hazard is present.
Recommended Actions & Workarounds
If your installation requires positively grounded network switches or you have detected voltage across mounting hardware, implement one of the following measures:
- Isolate Mounting Hardware: Install non-conductive hardware (such as nylon standoffs, non-conductive washers, or insulated mounting brackets) to physically isolate any electrical path between the mounting surface and operator touchpoints.
- Verify Switch Power Architecture: Verify the power supply grounding specifications of your network switches with your IT or network infrastructure team. Where possible, utilize isolated or conventional negative-ground PoE switches.
- Use an Isolated Power Source: If a positively grounded switch cannot be replaced or isolated, power the I-Series unit using the standard Elo AC/DC auxiliary power supply brick or an isolated inline PoE midspan injector.
Need Further Assistance?
If you have questions regarding your mounting setup or need assistance confirming your PoE power environment, please reach out to Elo Technical Support or submit a support ticket via your Elo customer portal.